PSEL=DIV2, ACTION=NONE
3.3V Brown-Out Detector (BOD33) Control
ENABLE | Enable |
HYST | Hysteresis |
ACTION | BOD33 Action 0 (NONE): No action 1 (RESET): The BOD33 generates a reset 2 (INTERRUPT): The BOD33 generates an interrupt |
RUNSTDBY | Run in Standby |
MODE | Operation Mode |
CEN | Clock Enable |
PSEL | Prescaler Select 0 (DIV2): Divide clock by 2 1 (DIV4): Divide clock by 4 2 (DIV8): Divide clock by 8 3 (DIV16): Divide clock by 16 4 (DIV32): Divide clock by 32 5 (DIV64): Divide clock by 64 6 (DIV128): Divide clock by 128 7 (DIV256): Divide clock by 256 8 (DIV512): Divide clock by 512 9 (DIV1K): Divide clock by 1024 10 (DIV2K): Divide clock by 2048 11 (DIV4K): Divide clock by 4096 12 (DIV8K): Divide clock by 8192 13 (DIV16K): Divide clock by 16384 14 (DIV32K): Divide clock by 32768 15 (DIV64K): Divide clock by 65536 |
LEVEL | BOD33 Threshold Level |